Added ww_on-for-timer command for easier controlling hot water production and some minor bugfixes
git-svn-id: https://fhem.svn.sourceforge.net/svnroot/fhem/trunk/fhem@1731 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -4226,13 +4226,17 @@ A line ending with \ will be concatenated with the next one, so long lines
|
||||
<li>ww_soll <temp><br>
|
||||
sets the hot water temperature<br>
|
||||
1.0 celsius resolution - temperature between 30 and 60 celsius</li>
|
||||
<li>ww_betriebsart [automatik|nacht|tag]</li>
|
||||
<li>ww_betriebsart [automatik|nacht|tag]<br>
|
||||
sets the working mode for hot water<br>
|
||||
<ul>
|
||||
<li>automatik: hot water production according to the working modes of both heating circuits</li>
|
||||
<li>nacht: no hot water at all</li>
|
||||
<li>tag: manual permanent hot water</li>
|
||||
</ul></li>
|
||||
<li>ww_on-for-timer [period]<br>
|
||||
start hot water production for the given period<br>
|
||||
period must have the format HH:MM<br>
|
||||
ww_betriebsart is set according to the attribut ww_timermode. For switching-off hot water a single one-time at command is automatically generated which will set ww_betriebsart back to nacht</li>
|
||||
<li>hk1_programm [eigen|familie|frueh|spaet|vormittag|nachmittag|mittag|single|senior]<br>
|
||||
sets the timer program for heating circuit 1<br>
|
||||
<ul>
|
||||
@@ -4294,6 +4298,11 @@ A line ending with \ will be concatenated with the next one, so long lines
|
||||
All UNKNOWN events are ignored too, most of them were only seen
|
||||
directly after setting the device into logmode.
|
||||
</li>
|
||||
<a name="ww_timermode"></a>
|
||||
<li>ww_timermode [automatik|tag]<br>
|
||||
Defines the working mode for the ww_on-for-timer command (default is tag).<br>
|
||||
ww_on-for-timer will set the ww_betriebsart of the heater according to this attribute.
|
||||
</li>
|
||||
|
||||
</ul>
|
||||