76_SolarForecast: contrib Version 1.59.6
git-svn-id: https://svn.fhem.de/fhem/trunk@30446 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -162,7 +162,7 @@ BEGIN {
|
||||
my %vNotesIntern = (
|
||||
"1.59.6" => "24.10.2025 ___ownSpecGetFWwidget: handling of line breaks in attributes & can hamdle a key=value pair separateley ".
|
||||
"Width of a text field in graphicHeaderOwnspec fixed to 10, edit commandref ".
|
||||
"__batChargeOptTargetPower: use an average for the charging power if optPower set and charging target are not achievable ".
|
||||
"__batChargeOptTargetPower: use an average for the charging power if smartPower set and charging target are not achievable ".
|
||||
"__createOwnSpec: an empty field can be created within a line by simply using a colon (:). ".
|
||||
"add new key pvshare to CustomerXX attributes -> __setConsRcmdState add PV share calculation ".
|
||||
"___doPlanning: code improvements and implement PV share needed ",
|
||||
@@ -12272,12 +12272,12 @@ sub __batChargeOptTargetPower {
|
||||
}
|
||||
}
|
||||
else { # Tagesziel nicht erreichbar: Aufschlag potenziert (zweifach wirksam)
|
||||
$target *= (1 + $otpMargin / 100) ** 2;
|
||||
|
||||
if ($strategy eq 'smartPower') { # smartPower: agressivere Ladeleistung
|
||||
$hs2sunset -= 1;
|
||||
$target = $runwhneed > 0 && $hs2sunset > 0 ? $runwhneed / $hs2sunset : $target;
|
||||
}
|
||||
|
||||
$target *= (1 + $otpMargin / 100) ** 2;
|
||||
}
|
||||
|
||||
my $gfeedin = CurrentVal ($name, 'gridfeedin', 0); # aktuelle Netzeinspeisung
|
||||
@@ -27205,8 +27205,8 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> <b>power</b> </td><td>Power consumption of the consumer in W. This can be the nominal power according to the data sheet or a dynamically specified reference value. </td></tr>
|
||||
<tr><td> </td><td>(can be set to "0") </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>pvshare</b> </td><td>Defines the PV share of consumer power (key ‘power’) that is considered sufficient for the consumer. (optional) </td></tr>
|
||||
<tr><td> </td><td>The setting 100% defines a required PV surplus of at least ‘power’. With 0%, the consumer does not require any PV surplus. </td></tr>
|
||||
<tr><td> <b>pvshare</b> </td><td>The key can be used to specify the desired percentage of PV power to cover the power consumption 'power'. (optional) </td></tr>
|
||||
<tr><td> </td><td>The setting 100% defines a required PV surplus of at least 'power'. With 0%, the consumer does not require any PV surplus. </td></tr>
|
||||
<tr><td> </td><td>Value: <b>0..100</b>, default: 100 (%) </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>switchdev</b> </td><td>The specified <device> is assigned to the consumer as a switch device (optional). Switching operations are performed with this device. </td></tr>
|
||||
@@ -29891,7 +29891,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<br><br>
|
||||
|
||||
Der Schlüssel <b>power</b> gibt die Leistungsaufnahme des Verbrauchers an. Mit dem Schlüssel <b>pvshare</b> kann der gewünschte
|
||||
prozentuale PV-Anteil zur Deckung der Leistungsaufnahme festgelgt werden. <br>
|
||||
prozentuale PV-Anteil zur Deckung der Leistungsaufnahme festgelegt werden. <br>
|
||||
Abhängig von diesen Werten werden die Schaltzeiten des Verbrauchers geplant und der Zyklus des Verbrauchers in Abhängigkeit
|
||||
des ausreichenden PV-Überschußes zum Einplanungszeitpunkt gestartet. <br>
|
||||
Ist <b>power=0</b> oder <b>pvshare=0</b> gesetzt, wird der Verbraucher unabhängig von einem ausreichend vorhandenem PV-Überschuß
|
||||
@@ -29922,7 +29922,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> <b>power</b> </td><td>Leistungsaufnahme des Verbrauchers in W. Es kann die nominale Leistung gemäß Datenblatt oder ein dynamisch vorgegebener Richtwert sein. </td></tr>
|
||||
<tr><td> </td><td>(kann auf "0" gesetzt werden) </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>pvshare</b> </td><td>Legt den PV-Anteil der Verbraucherleistung (Schlüssel 'power') fest, der als ausreichend für den Verbraucher gewertet wird. (optional) </td></tr>
|
||||
<tr><td> <b>pvshare</b> </td><td>Mit dem Schlüssel kann der gewünschte prozentuale PV-Anteil zur Deckung der Leistungsaufnahme 'power' festgelegt werden. (optional) </td></tr>
|
||||
<tr><td> </td><td>Die Einstellung 100% definiert einen benötigten PV-Überschuß von mindestens 'power'. Mit 0% benötigt der Verbraucher keinen PV-Überschuß. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>0..100</b>, default: 100 (%) </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
|
||||