@@ -27277,10 +27277,12 @@ to ensure that the system configuration is correct.
<tr><td> <b>stepSoC</b> </td><td>Optional step size for optimal SoC calculation (Battery_OptimumTargetSoC_XX) in %. </td></tr> <tr><td> <b>stepSoC</b> </td><td>Optional step size for optimal SoC calculation (Battery_OptimumTargetSoC_XX) in %. </td></tr>
<tr><td> </td><td>The specification 'stepSoC=0' deactivates the SoC management and sets </td></tr> <tr><td> </td><td>The specification 'stepSoC=0' deactivates the SoC management and sets </td></tr>
<tr><td> </td><td>Battery_OptimumTargetSoC_XX to the value 'lowSoC'. </td></tr> <tr><td> </td><td>Battery_OptimumTargetSoC_XX to the value 'lowSoC'. </td></tr>
<tr><td> </td><td><b>Note:</b> The relationship careCycle * stepSoC = 100 should be observed! </td></tr>
<tr><td> </td><td>Wert: <b>0..5</b>, default: 5 </td></tr> <tr><td> </td><td>Wert: <b>0..5</b>, default: 5 </td></tr>
<tr><td> </td><td> </td></tr> <tr><td> </td><td> </td></tr>
<tr><td> <b>careCycle</b> </td><td>Maximum interval in days between two charge states of at least 'maxSoC' that should not be </td></tr> <tr><td> <b>careCycle</b> </td><td>Maximum interval in days between two charge states of at least 'maxSoC' that should not be </td></tr>
<tr><td> </td><td>exceeded if possible. The specification is optional (default: 20) </td></tr> <tr><td> </td><td>exceeded if possible. The specification is optional (default: 20) </td></tr>
<tr><td> </td><td><b>Note:</b> The relationship careCycle * stepSoC = 100 should be observed! </td></tr>
<tr><td> </td><td> </td></tr> <tr><td> </td><td> </td></tr>
<tr><td> <b>lcSlot</b> </td><td>A daily time window is defined in which the charging control of the module should be active </td></tr> <tr><td> <b>lcSlot</b> </td><td>A daily time window is defined in which the charging control of the module should be active </td></tr>
<tr><td> </td><td>for this battery. Outside the time window, the battery charge is released </td></tr> <tr><td> </td><td>for this battery. Outside the time window, the battery charge is released </td></tr>
@@ -29986,10 +29988,12 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
<tr><td> <b>stepSoC</b> </td><td>Optionale Schrittweite zur optimalen SoC-Berechnung (Battery_OptimumTargetSoC_XX) in %. </td></tr> <tr><td> <b>stepSoC</b> </td><td>Optionale Schrittweite zur optimalen SoC-Berechnung (Battery_OptimumTargetSoC_XX) in %. </td></tr>
<tr><td> </td><td>Mit der Angabe 'stepSoC=0' wird das SoC-Management deaktiviert und Battery_OptimumTargetSoC_XX </td></tr> <tr><td> </td><td>Mit der Angabe 'stepSoC=0' wird das SoC-Management deaktiviert und Battery_OptimumTargetSoC_XX </td></tr>
<tr><td> </td><td>auf den Wert 'lowSoC' gesetzt. </td></tr> <tr><td> </td><td>auf den Wert 'lowSoC' gesetzt. </td></tr>
<tr><td> </td><td><b>Hinweis:</b> Die Beziehung 'careCycle * stepSoC = 100' sollte eingehalten werden! </td></tr>
<tr><td> </td><td>Wert: <b>0..5</b>, default: 5 </td></tr> <tr><td> </td><td>Wert: <b>0..5</b>, default: 5 </td></tr>
<tr><td> </td><td> </td></tr> <tr><td> </td><td> </td></tr>
<tr><td> <b>careCycle</b> </td><td>maximaler Abstand in Tagen, der zwischen zwei Ladungszuständen von mindestens 'maxSoC' </td></tr> <tr><td> <b>careCycle</b> </td><td>maximaler Abstand in Tagen, der zwischen zwei Ladungszuständen von mindestens 'maxSoC' </td></tr>
<tr><td> </td><td>möglichst nicht überschritten werden soll. Die Angabe ist optional (default: 20) </td></tr> <tr><td> </td><td>möglichst nicht überschritten werden soll. Die Angabe ist optional (default: 20) </td></tr>
<tr><td> </td><td><b>Hinweis:</b> Die Beziehung 'careCycle * stepSoC = 100' sollte eingehalten werden! </td></tr>
<tr><td> </td><td> </td></tr> <tr><td> </td><td> </td></tr>
<tr><td> <b>lcSlot</b> </td><td>Es wird ein tägliches Zeitfenster festgelegt, in dem die Ladesteuerung des Moduls für diese </td></tr> <tr><td> <b>lcSlot</b> </td><td>Es wird ein tägliches Zeitfenster festgelegt, in dem die Ladesteuerung des Moduls für diese </td></tr>
<tr><td> </td><td>Batterie aktiv sein soll. Außerhalb des Zeitfensters wird die Batterieladung mit voller </td></tr> <tr><td> </td><td>Batterie aktiv sein soll. Außerhalb des Zeitfensters wird die Batterieladung mit voller </td></tr>