sucRouteDel
Delete static return routes to SUC/SIS node.
-
Class ALARM (NOTIFICATION), V4
+
Class ALARM
alarmnotification <alarmType> (on|off)
Enable (on) or disable (off) the sending of unsolicited reports for
the alarm type <alarmType>. A list of supported alarm types of the
- device can be obtained with the "alarmTypeSupported" command. The
+ device can be obtained with the alarmTypeSupported command. The
name of the alarm type is case insensitive. Sending of an unsolicted
- notification only work to associated nodes, broadcasting is not
+ notification only works to associated nodes, broadcasting is not
allowed, so associations have to be set up. This command is
specified in version 2.
Note:
- The name of the class ALARM was renamend to NOTIFICATION in
+ The name of the class ALARM was renamed to NOTIFICATION in
version 3 of the Zwave specification. Due to backward compatibility
reasons the class will be always referenced as ALARM in FHEM,
regardless of the version.
@@ -4815,13 +4815,6 @@ s2Hex($)
location LOCATION
Store LOCATION in the EEPROM. Note: only ASCII is supported.
-
Class NOTIFICATION
- Note:
- The name of the class ALARM was renamend to NOTIFICATION in
- version 3 of the Zwave specification. Due to backward compatibility
- reasons the class will be always referenced as ALARM in FHEM,
- regardless of the version. Please refer to class ALARM.
-
Class POWERLEVEL
Class is only used in an installation or test situation
powerlevel level timeout/s
@@ -5086,7 +5079,7 @@ s2Hex($)
Since this information is stored in the dongle, the information will be
returned directly even for WAKE_UP devices.
-
Class ALARM (NOTIFICATION), V4
+
Class ALARM
alarm <alarmId>
return the value for the (decimal) alarmId. The value is device
specific. This command is specified in version 1 and should only
@@ -5108,14 +5101,9 @@ s2Hex($)
commands. This command is specified in version 2.
alarmEventSupported <alarmType>
Returns a list of the supported events for the specified alarm type.
- The numbers of the events can be used as parameters in the
+ The number of the events can be used as parameter in the
"alarmWithTypeEvent" command. This command is specified in
version 3.
- Note:
- The name of the class ALARM was renamend to NOTIFICATION in
- version 3 of the Zwave specification. Due to backward compatibility
- reasons the class will be always referenced as ALARM in FHEM,
- regardless of the version.
Class ASSOCIATION
association groupId
@@ -5280,13 +5268,6 @@ s2Hex($)
location
Get the location from the EEPROM. Note: only ASCII is supported.
-
Class NOTIFICATION
- Note:
- The name of the class ALARM was renamend to NOTIFICATION in
- version 3 of the Zwave specification. Due to backward compatibility
- reasons the class will be always referenced as ALARM in FHEM,
- regardless of the version. Please refer to class ALARM.
-
Class POWERLEVEL
powerlevel
Get the current powerlevel and remaining time in this level.
@@ -5502,21 +5483,21 @@ s2Hex($)
text after an update.
extendedAlarmReadings
Some devices support more than one alarm type, this attribute
- select which type of reading is used for the reports of the ALARM
+ selects which type of reading is used for the reports of the ALARM
(or NOTIFICATION) class:
- A value of "0" select a combined, single reading ("alarm") for
+ A value of "0" selects a combined, single reading ("alarm") for
all alarm types of the device. Subsequent reports of different
alarm types will overwrite each other. This is the default setting
and the former behavior.
- A value of "1" select separate alarm readings for each alarm type
- of the device. The readingings are named "alarm_<alarmtype>.
+ A value of "1" selects separate alarm readings for each alarm type
+ of the device. The readings are named "alarm_<alarmtype>.
This can also be selected if only one alarmtype is supported by
- the device. This reading also contain the status of the
- alarmnotification. For compatibility reasons this is currently
+ the device. This reading also contains the status of the
+ alarm notification. For compatibility reasons this is currently
not supported with the combined reading.
- A value of "2" select both of the above and create a combined and
+ A value of "2" selects both of the above and creates the combined and
the seperate readings at the same time, this should only be used
- if really needed as more or less duplicate events are generated.
+ if really needed as duplicate events are generated.
ignore
@@ -5591,16 +5572,16 @@ s2Hex($)
"alarm_<alarmType>.
Devices with class version 1 support: alarm_type_X:level Y
For higher class versions more detailed events with 100+ different
- strings in the form alarm:<string>
- (or alarm_<alarmType>:<string>) are generated.
- For the combined reading, the name of the alarm type is part of
- the reading event, for separate readings it is part of the
- reading name.
- If a cleared event can be identified, the string "Event cleared:"
- is reported before the event details.
- The seperate readings also contain the status of the
- alarmnotification. For compatibility reasons this is currently
- not supported with the combined reading.
+ strings in the form alarm:<string>
+ (or alarm_<alarmType>:<string>) are generated.
+ For the combined reading, the name of the alarm type is part of
+ the reading event, for separate readings it is part of the
+ reading name.
+ If a cleared event can be identified, the string "Event cleared:"
+ is reported before the event details.
+ The seperate readings also contain the status of the
+ alarm / notification. For compatibility reasons this is currently
+ not supported with the combined reading.
Class APPLICATION_STATUS