LUXTRONIK Docu correction

git-svn-id: https://svn.fhem.de/fhem/trunk@4857 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
tpoitzsch
2014-02-09 15:35:23 +00:00
parent f60924c576
commit a0d9abaaa8

View File

@@ -1,5 +1,7 @@
############################################################### ###############################################################
# #
# 23_LUXTRONIK2.pm
#
# Copyright notice # Copyright notice
# #
# (c) 2012,2014 Torsten Poitzsch (torsten.poitzsch@gmx.de) # (c) 2012,2014 Torsten Poitzsch (torsten.poitzsch@gmx.de)
@@ -53,7 +55,7 @@ LUXTRONIK2_Initialize($)
$hash->{UndefFn} = "LUXTRONIK2_Undefine"; $hash->{UndefFn} = "LUXTRONIK2_Undefine";
$hash->{NotifyFn} = "LUXTRONIK2_Notify"; $hash->{NotifyFn} = "LUXTRONIK2_Notify";
$hash->{SetFn} = "LUXTRONIK2_Set"; $hash->{SetFn} = "LUXTRONIK2_Set";
$hash->{AttrFn} = "LUXTRONIK2_Attr"; $hash->{AttrFn} = "LUXTRONIK2_Attr";
$hash->{AttrList} = "disable:0,1 ". $hash->{AttrList} = "disable:0,1 ".
"allowSetParameter:0,1 ". "allowSetParameter:0,1 ".
"autoSynchClock:slider,10,5,300 ". "autoSynchClock:slider,10,5,300 ".
@@ -155,10 +157,31 @@ LUXTRONIK2_Notify(@) {
if ( exists( $hash->{READINGS}{$oldReading} ) ) { if ( exists( $hash->{READINGS}{$oldReading} ) ) {
delete($hash->{READINGS}{$oldReading}); delete($hash->{READINGS}{$oldReading});
Log3 $name,2,"$name: !!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'"; Log3 $name,2,"$name: !!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'";
}
} }
} }
} return;
return; }
sub ########################################
LUXTRONIK2_Attr(@)
{
my ($cmd,$name,$aName,$aVal) = @_;
# $cmd can be "del" or "set"
# $name is device name
# aName and aVal are Attribute name and value
if ($cmd eq "set") {
if ($aName eq "1allowSetParameter") {
eval { qr/$aVal/ };
if ($@) {
Log3 $name, 3, "LUXTRONIK2: Invalid allowSetParameter in attr $name $aName $aVal: $@";
return "Invalid allowSetParameter $aVal";
}
}
}
return undef;
} }
@@ -241,25 +264,6 @@ LUXTRONIK2_Set($$@)
return "Unknown argument $cmd, choose one of $list"; return "Unknown argument $cmd, choose one of $list";
} }
sub ########################################
LUXTRONIK2_Attr(@)
{
my ($cmd,$name,$aName,$aVal) = @_;
# $cmd can be "del" or "set"
# $name is device name
# aName and aVal are Attribute name and value
if ($cmd eq "set") {
if ($aName eq "1allowSetParameter") {
eval { qr/$aVal/ };
if ($@) {
Log3 $name, 3, "LUXTRONIK2: Invalid allowSetParameter in attr $name $aName $aVal: $@";
return "Invalid allowSetParameter $aVal";
}
}
}
return undef;
}
sub ######################################## sub ########################################
LUXTRONIK2_GetUpdate($) LUXTRONIK2_GetUpdate($)
@@ -296,7 +300,8 @@ LUXTRONIK2_DoUpdate($)
my $readingStartTime = time(); my $readingStartTime = time();
Log3 $name, 5, "$name: Opening connection to host ".$host; Log3 $name, 5, "$name: Opening connection to host ".$host;
my $socket = new IO::Socket::INET ( PeerAddr => $host, my $socket = new IO::Socket::INET (
PeerAddr => $host,
PeerPort => 8888, PeerPort => 8888,
# Type = SOCK_STREAM, # probably needed on some systems # Type = SOCK_STREAM, # probably needed on some systems
Proto => 'tcp' Proto => 'tcp'
@@ -1270,18 +1275,19 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2"></a> <a name="LUXTRONIK2"></a>
<h3>LUXTRONIK2</h3> <h3>LUXTRONIK2</h3>
<ul> <ul>
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.<br> Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.
<br>
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN). It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
<br> <br>
<i>The modul is reported to work with firmware: V1.54C, V1.60, V1.69.</i> <i>The modul is reported to work with firmware: V1.54C, V1.60, V1.69.</i>
<br>&nbsp; <br>
&nbsp;
<br> <br>
<a name="LUXTRONIK2define"></a> <a name="LUXTRONIK2define"></a>
<b>Define</b> <b>Define</b>
<ul> <ul>
<code>define &lt;name&gt; LUXTRONIK2 &lt;IP-address&gt; [poll-interval]</code> <code>define &lt;name&gt; LUXTRONIK2 &lt;IP-address&gt; [poll-interval]</code><br>
<br>
If the pool interval is omitted, it is set to 300 (seconds). Smallest possible value is 30. If the pool interval is omitted, it is set to 300 (seconds). Smallest possible value is 30.
<br> <br>
Example: <code>define Heizung LUXTRONIK2 192.168.0.12 600</code> Example: <code>define Heizung LUXTRONIK2 192.168.0.12 600</code>
@@ -1313,18 +1319,26 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2attr"></a> <a name="LUXTRONIK2attr"></a>
<b>Attributes</b> <b>Attributes</b>
<ul> <ul>
<li><code>statusHTML</code><br> <li><code>statusHTML</code>
If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the <a href="#FLOORPLAN">FLOORPLAN</a> module.<br> <br>
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.</li> If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the <a href="#FLOORPLAN">FLOORPLAN</a> module.
<li><code>doStatistics &lt; 0 | 1 &gt;</code><br> <br>
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.</li>
<li><code>doStatistics &lt; 0 | 1 &gt;</code>
<br>
Calculates statistic values: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)</i></li> Calculates statistic values: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)</i></li>
<li><code>allowSetParameter &lt; 0 | 1 &gt;</code><br> <li><code>allowSetParameter &lt; 0 | 1 &gt;</code>
<br>
The <a href="#LUXTRONIK2set">parameters</a> of the heat pump controller can only be changed if this attribut is set to 1.</li> The <a href="#LUXTRONIK2set">parameters</a> of the heat pump controller can only be changed if this attribut is set to 1.</li>
<li><code>autoSynchClock &lt;delay&gt;</code><br> <li><code>autoSynchClock &lt;delay&gt;</code>
Corrects the clock of the heatpump automatically if a certain <i>delay</i> (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.<br> <br>
Corrects the clock of the heatpump automatically if a certain <i>delay</i> (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.
<br>
<i>(A 'delayDeviceTimeCalc' &lt;= 2 s can be caused by the internal calculation interval of the heat pump controller.)</i></li> <i>(A 'delayDeviceTimeCalc' &lt;= 2 s can be caused by the internal calculation interval of the heat pump controller.)</i></li>
<li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code><br> <li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code>
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.<br> <br>
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.
<br>
If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.</li> If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.</li>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li> <li><a href="#readingFnAttributes">readingFnAttributes</a></li>
</ul> </ul>
@@ -1361,12 +1375,21 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<b>Set</b><br> <b>Set</b><br>
<ul> <ul>
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden. Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden.
<li>opModeHotWater &lt;Betriebsmodus&gt; - Betriebsmodus des Hei&szlig;wasserboilers ( Auto | Party | Off )</l> <li><code>opModeHotWater &lt;Betriebsmodus&gt;</code>
<li>hotWaterTemperatureTarget &lt;Temperatur&gt; - Soll-Temperatur des Hei&szlig;wasserboilers in &deg;C</li> <br>
<li>INTERVAL &lt;Abfrageinterval&gt; - Abfrageinterval in Sekunden</li> Betriebsmodus des Hei&szlig;wasserboilers ( Auto | Party | Off )</l>
<li>statusRequest - Aktualisieren der Ger&auml;tewerte</li> <li><code>hotWaterTemperatureTarget &lt;Temperatur&gt;</code>
<li>synchClockHeatPump - Abgleich der Uhr der Steuerung mit der FHEM Zeit. <br> <br>
<b>!! Diese &Auml;nderung geht verloren, sobald die Steuerung ausgeschaltet wird!!</b></li> Soll-Temperatur des Hei&szlig;wasserboilers in &deg;C</li>
<li><code>INTERVAL &lt;Abfrageinterval&gt;</code>
<br>
Abfrageinterval in Sekunden</li>
<li><code>statusRequest</code>
<br>
Aktualisieren der Ger&auml;tewerte</li>
<li><code>synchClockHeatPump</code>
<br>
Abgleich der Uhr der Steuerung mit der FHEM Zeit. <b>Diese &Auml;nderung geht verloren, sobald die Steuerung ausgeschaltet wird!!</b></li>
</ul> </ul>
<br> <br>
@@ -1380,17 +1403,21 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2attr"></a> <a name="LUXTRONIK2attr"></a>
<b>Attribute</b> <b>Attribute</b>
<ul> <ul>
<li>statusHTML<br> <li><code>statusHTML</code><br>
wenn gesetzt, dann wird ein HTML-formatierter Wert "floorplanHTML" erzeugt, welcher vom Modul <a href="#FLOORPLAN">FLOORPLAN</a> genutzt werden kann.<br> wenn gesetzt, dann wird ein HTML-formatierter Wert "floorplanHTML" erzeugt, welcher vom Modul <a href="#FLOORPLAN">FLOORPLAN</a> genutzt werden kann.<br>
Momentan wird nur gepr&uuml;ft, ob der Wert dieses Attributes ungleich NULL ist, der entsprechende Ger&auml;tewerte besteht aus dem aktuellen W&auml;rmepumpenstatus und der Heizwassertemperatur.</li> Momentan wird nur gepr&uuml;ft, ob der Wert dieses Attributes ungleich NULL ist, der entsprechende Ger&auml;tewerte besteht aus dem aktuellen W&auml;rmepumpenstatus und der Heizwassertemperatur.</li>
<li>doStatistics &lt; 0 | 1 &gt;<br> <li><code>doStatistics &lt; 0 | 1 &gt;</code>
Berechnet statistische Werte: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (W<>rmeverlust des Boilers)</i></li> <br>
<li>allowSetParameter &lt; 0 | 1 &gt;<br> Berechnet statistische Werte: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (W&auml;rmeverlust des Boilers)</i></li>
Die internen <a href="#LUXTRONIK2set">Parameter</a> der W&auml;rmepumpensteuerung k&ouml;nnen nur ge&auml;ndert werden, wenn dieses Attribut auf 1 gesetzt ist.</li> <li><code>allowSetParameter &lt; 0 | 1 &gt;</code>
<li>autoSynchClock &lt;Zeitunterschied&gt;<br> <br>
Die internen <a href="#LUXTRONIK2set">Parameter</a> der W&auml;rmepumpensteuerung k&ouml;nnen nur ge&auml;ndert werden, wenn dieses Attribut auf 1 gesetzt ist.</li>
<li><code>autoSynchClock &lt;Zeitunterschied&gt;</code>
<br>
Die Uhr der W&auml;rmepumpe wird automatisch korrigiert, wenn ein gewisser <i>Zeitunterschied</i> (10 s - 600 s) gegen&uuml;ber der FHEM Zeit erreicht ist. Zuvor wird die Kompatibilit&auml;t der Firmware &uuml;berpr&uuml;ft.<br> Die Uhr der W&auml;rmepumpe wird automatisch korrigiert, wenn ein gewisser <i>Zeitunterschied</i> (10 s - 600 s) gegen&uuml;ber der FHEM Zeit erreicht ist. Zuvor wird die Kompatibilit&auml;t der Firmware &uuml;berpr&uuml;ft.<br>
<i>(Ein Ger&auml;tewert 'delayDeviceTimeCalc' &lt;= 2 s ist auf die internen Berechnungsintervale der W&auml;rmepumpensteuerung zur&uuml;ckzuf&uuml;hren.)</i></li> <i>(Ein Ger&auml;tewert 'delayDeviceTimeCalc' &lt;= 2 s ist auf die internen Berechnungsintervale der W&auml;rmepumpensteuerung zur&uuml;ckzuf&uuml;hren.)</i></li>
<li>ignoreFirmwareCheck &lt; 0 | 1 &gt;<br> <li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code>
<br>
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden. Wenn dieses Attribute auf 1 gesetzt ist, dann wird der Firmware-Test ignoriert und neue Firmware kann getestet werden. Dieses Attribut wird jedoch ignoriert, wenn die Steuerungs-Firmware bereits als nicht kompatibel berichtet wurde.</li> Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden. Wenn dieses Attribute auf 1 gesetzt ist, dann wird der Firmware-Test ignoriert und neue Firmware kann getestet werden. Dieses Attribut wird jedoch ignoriert, wenn die Steuerungs-Firmware bereits als nicht kompatibel berichtet wurde.</li>