76_SolarForecast: Version 1.58.3
git-svn-id: https://svn.fhem.de/fhem/trunk@30306 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -1,5 +1,6 @@
|
|||||||
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
||||||
# Do not insert empty lines here, update check depends on it
|
# Do not insert empty lines here, update check depends on it
|
||||||
|
- feature: 76_SolarForecast: Version 1.58.3
|
||||||
- bugfix: 98_vitoconnect: Not a HASH reference in vitoconnect_action
|
- bugfix: 98_vitoconnect: Not a HASH reference in vitoconnect_action
|
||||||
- feature: 98_vitoconnect: Refresh expired token in set action
|
- feature: 98_vitoconnect: Refresh expired token in set action
|
||||||
- bugfix: 76_SolarForecast: Version 1.58.2
|
- bugfix: 76_SolarForecast: Version 1.58.2
|
||||||
|
|||||||
@@ -160,6 +160,7 @@ BEGIN {
|
|||||||
|
|
||||||
# Versions History intern
|
# Versions History intern
|
||||||
my %vNotesIntern = (
|
my %vNotesIntern = (
|
||||||
|
"1.58.3" => "17.09.2025 __batChargeOptTargetPower: minor code change, consider bpinmax & lcintime ",
|
||||||
"1.58.2" => "11.09.2025 __batChargeOptTargetPower: a lot of Code improvements, Attr flowGraphicControl->shiftx: unrestrict possible values ",
|
"1.58.2" => "11.09.2025 __batChargeOptTargetPower: a lot of Code improvements, Attr flowGraphicControl->shiftx: unrestrict possible values ",
|
||||||
"1.58.1" => "08.09.2025 edit comref, ctrlBatSocManagementXX->safetyMargin: Separate specification of surcharges for calculation of load ".
|
"1.58.1" => "08.09.2025 edit comref, ctrlBatSocManagementXX->safetyMargin: Separate specification of surcharges for calculation of load ".
|
||||||
"clearance and performance optimization ",
|
"clearance and performance optimization ",
|
||||||
@@ -1088,8 +1089,8 @@ my %htitles = (
|
|||||||
DE => qq{SoC Prognose} },
|
DE => qq{SoC Prognose} },
|
||||||
socbaths => { EN => qq{SoC at the end of the hour},
|
socbaths => { EN => qq{SoC at the end of the hour},
|
||||||
DE => qq{SoC am Ende der Stunde} },
|
DE => qq{SoC am Ende der Stunde} },
|
||||||
lcactive => { EN => qq{Charge management activated},
|
lcready => { EN => qq{Charge management ready},
|
||||||
DE => qq{Lademanagement aktiviert} },
|
DE => qq{Lademanagement bereit} },
|
||||||
bcharrel => { EN => qq{Charging release (activate release for charging the battery if necessary)},
|
bcharrel => { EN => qq{Charging release (activate release for charging the battery if necessary)},
|
||||||
DE => qq{Ladefreigabe (evtl. Freigabe zum Laden der Batterie aktivieren)} },
|
DE => qq{Ladefreigabe (evtl. Freigabe zum Laden der Batterie aktivieren)} },
|
||||||
bncharel => { EN => qq{only charge if the feed-in limit is exceeded},
|
bncharel => { EN => qq{only charge if the feed-in limit is exceeded},
|
||||||
@@ -11816,7 +11817,7 @@ sub _batChargeMgmt {
|
|||||||
###############################################################
|
###############################################################
|
||||||
my $spswh = max (0, sprintf ("%.0f", $fceff));
|
my $spswh = max (0, sprintf ("%.0f", $fceff));
|
||||||
|
|
||||||
if ($today) { # nur Heute wenn Überschuß vorliegt
|
if ($today) { # nur Heute
|
||||||
$hsurp->{$hod}{hod} = $hod;
|
$hsurp->{$hod}{hod} = $hod;
|
||||||
$hsurp->{$hod}{nhr} = $nhr;
|
$hsurp->{$hod}{nhr} = $nhr;
|
||||||
$hsurp->{$hod}{surpls} = $surpls; # Überschuß in Wh der Stunde
|
$hsurp->{$hod}{surpls} = $surpls; # Überschuß in Wh der Stunde
|
||||||
@@ -11825,7 +11826,9 @@ sub _batChargeMgmt {
|
|||||||
$hsurp->{$hod}{$bn}{whneedmanaged} = $whneed; # benötigte Ladeenergie Batterie x gemäß Ladesteuerung
|
$hsurp->{$hod}{$bn}{whneedmanaged} = $whneed; # benötigte Ladeenergie Batterie x gemäß Ladesteuerung
|
||||||
$hsurp->{$hod}{$bn}{socwh} = $socwh;
|
$hsurp->{$hod}{$bn}{socwh} = $socwh;
|
||||||
$hsurp->{$hod}{$bn}{batinstcap} = $batinstcap;
|
$hsurp->{$hod}{$bn}{batinstcap} = $batinstcap;
|
||||||
|
$hsurp->{$hod}{$bn}{bpinmax} = $bpinmax; # max. mögliche Ladeleistung
|
||||||
$hsurp->{$hod}{$bn}{otpMargin} = $otpMargin; # Sicherheitszuschlag für Berechnungen
|
$hsurp->{$hod}{$bn}{otpMargin} = $otpMargin; # Sicherheitszuschlag für Berechnungen
|
||||||
|
$hsurp->{$hod}{$bn}{lcintime} = $lcintime; # Ladesteuerung "In Time" oder "nicht In Time"
|
||||||
}
|
}
|
||||||
|
|
||||||
# prognostizierten Daten in pvHistory speichern
|
# prognostizierten Daten in pvHistory speichern
|
||||||
@@ -11841,8 +11844,8 @@ sub _batChargeMgmt {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
# Erstellung Mindest Ladeleistung
|
# leistungsoptimierte Beladungssteuerung
|
||||||
###################################
|
##########################################
|
||||||
$paref->{hsurp} = $hsurp;
|
$paref->{hsurp} = $hsurp;
|
||||||
__batChargeOptTargetPower ($paref);
|
__batChargeOptTargetPower ($paref);
|
||||||
delete $paref->{hsurp};
|
delete $paref->{hsurp};
|
||||||
@@ -11910,18 +11913,25 @@ sub __batChargeOptTargetPower {
|
|||||||
$sphrs-- if($spls); # Reststunden mit Überschuß
|
$sphrs-- if($spls); # Reststunden mit Überschuß
|
||||||
|
|
||||||
for my $sbn (sort @batteries) { # jede Batterie
|
for my $sbn (sort @batteries) { # jede Batterie
|
||||||
my $runwh = defined $hsurp->{$shod}{$sbn}{fcnextwh} ? # Auswahl des zu verwenden Prognose-SOC (Wh)
|
if (!$hsurp->{$shod}{$sbn}{lcintime}) { # Ladesteuerung nicht "In Time"
|
||||||
|
$hsurp->{$shod}{$sbn}{pneedmin} = $hsurp->{$shod}{$sbn}{bpinmax};
|
||||||
|
next;
|
||||||
|
}
|
||||||
|
|
||||||
|
my $crgwh = BatteryVal ($name, $sbn, 'bchargewh', 0); # aktueller Ladezustand Batterie
|
||||||
|
my $runwh = defined $hsurp->{$shod}{$sbn}{fcnextwh} ? # Auswahl des zu verwendenden Prognose-SOC (Wh)
|
||||||
$hsurp->{$shod}{$sbn}{fcnextwh} :
|
$hsurp->{$shod}{$sbn}{fcnextwh} :
|
||||||
( $hsurp->{$shod}{nhr} eq '00' ?
|
( $hsurp->{$shod}{nhr} eq '00' ?
|
||||||
BatteryVal ($name, $sbn, 'bchargewh', 0) :
|
$crgwh :
|
||||||
$hsurp->{$shod}{$sbn}{socwh}
|
$hsurp->{$shod}{$sbn}{socwh}
|
||||||
);
|
);
|
||||||
|
|
||||||
my $bpinreduced = BatteryVal ($name, $sbn, 'bpinreduced', 0); # Standardwert wenn z.B. kein Überschuß oder Zwangsladung vom Grid
|
my $bpinreduced = BatteryVal ($name, $sbn, 'bpinreduced', 0); # Standardwert wenn z.B. kein Überschuß oder Zwangsladung vom Grid
|
||||||
|
|
||||||
if (!$spls) { # auf kleine Sollladeleistung setzen wenn kein Überschuß
|
if (!$spls) { # auf kleine Sollladeleistung setzen wenn kein Überschuß
|
||||||
$hsurp->{$shod}{$sbn}{pneedmin} = $bpinreduced;
|
#$hsurp->{$shod}{$sbn}{pneedmin} = $bpinreduced;
|
||||||
storeReading ('Battery_ChargeOptTargetPower_'.$sbn, $bpinreduced.' W') if($hsurp->{$shod}{nhr} eq '00');
|
$otp->{$sbn}{target} = $bpinreduced;
|
||||||
|
#storeReading ('Battery_ChargeOptTargetPower_'.$sbn, $bpinreduced.' W') if($hsurp->{$shod}{nhr} eq '00');
|
||||||
next;
|
next;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -11934,16 +11944,13 @@ sub __batChargeOptTargetPower {
|
|||||||
my $margin = defined $otpMargin ? $otpMargin : SFTYMARGIN_20;
|
my $margin = defined $otpMargin ? $otpMargin : SFTYMARGIN_20;
|
||||||
$needraw *= 1 + ($margin / 100); # Sicherheitsaufschlag
|
$needraw *= 1 + ($margin / 100); # Sicherheitsaufschlag
|
||||||
|
|
||||||
if ($spls - $needraw > $fipl) { # Einspeiselimit berücksichtigen
|
|
||||||
$needraw += ($spls - $needraw) - $fipl;
|
|
||||||
}
|
|
||||||
|
|
||||||
$needraw = max (0, $needraw);
|
$needraw = max (0, $needraw);
|
||||||
$hsurp->{$shod}{$sbn}{runwh} = sprintf "%.0f", $runwh;
|
$hsurp->{$shod}{$sbn}{runwh} = sprintf "%.0f", $runwh;
|
||||||
$hsurp->{$shod}{$sbn}{sphrs} = $sphrs; # Reststunden mit diesem Überschuß
|
$hsurp->{$shod}{$sbn}{sphrs} = $sphrs; # Reststunden mit diesem Überschuß
|
||||||
$hsurp->{$shod}{$sbn}{pneedmin} = sprintf "%.0f", $spls > $needraw ? # Mindestladeleistung bzw. Energie bei 1h (Wh)
|
my $pneedmin = sprintf "%.0f", $spls > $needraw ? # Mindestladeleistung bzw. Energie bei 1h (Wh)
|
||||||
$needraw ? $needraw : $bpinreduced :
|
$needraw ? $needraw : $bpinreduced :
|
||||||
$spls;
|
$spls;
|
||||||
|
$hsurp->{$shod}{$sbn}{pneedmin} = min ($pneedmin, $hsurp->{$shod}{$sbn}{bpinmax}); # Begrenzung auf max. mögliche Batterieleistung
|
||||||
|
|
||||||
my $newshod = sprintf "%02d", (int $shod + 1);
|
my $newshod = sprintf "%02d", (int $shod + 1);
|
||||||
$hsurp->{$newshod}{$sbn}{fcnextwh} = $runwh + $hsurp->{$shod}{$sbn}{pneedmin} if(defined $hsurp->{$newshod});
|
$hsurp->{$newshod}{$sbn}{fcnextwh} = $runwh + $hsurp->{$shod}{$sbn}{pneedmin} if(defined $hsurp->{$newshod});
|
||||||
@@ -11955,7 +11962,7 @@ sub __batChargeOptTargetPower {
|
|||||||
|
|
||||||
if ($hsurp->{$shod}{$sbn}{runwh} < $sbatinstcap) {
|
if ($hsurp->{$shod}{$sbn}{runwh} < $sbatinstcap) {
|
||||||
$otp->{$sbn}{maxvals}++;
|
$otp->{$sbn}{maxvals}++;
|
||||||
$otp->{$sbn}{sumneed} += $otp->{$sbn}{maxneed};
|
$otp->{$sbn}{sumneed} = $sbatinstcap - $crgwh;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -11968,17 +11975,29 @@ sub __batChargeOptTargetPower {
|
|||||||
next if(!defined $target);
|
next if(!defined $target);
|
||||||
|
|
||||||
my $avg = 0;
|
my $avg = 0;
|
||||||
my $mv = $otp->{$bn}{maxvals} // 0;
|
my $mv = $otp->{$bn}{maxvals};
|
||||||
my $sn = $otp->{$bn}{sumneed} // 0;
|
my $sn = $otp->{$bn}{sumneed} // 0;
|
||||||
$avg = sprintf "%.0f", ($sn / $mv) if($mv);
|
$avg = sprintf "%.0f", ($sn / $mv) if($mv);
|
||||||
$target = max ($avg, $target);
|
$target = max ($avg, $target);
|
||||||
|
|
||||||
|
my $gfeedin = CurrentVal ($name, 'gridfeedin', 0); # aktuelle Netzeinspeisung
|
||||||
|
my $bpin = CurrentVal ($name, 'batpowerinsum', 0); # aktuelle Batterie Ladeleistung (Summe über alle Batterien)
|
||||||
|
my $inc = 0;
|
||||||
|
|
||||||
|
if ( !$bpin && $gfeedin > $fipl ) {$inc = $gfeedin - $fipl} # Ladefreigabe wenn akt. keine Bat-Ladung UND akt. Einspeisung > Einspeiselimit der Anlage
|
||||||
|
if ( $bpin && ($gfeedin - $bpin) > $fipl ) {$inc = $bpin + (($gfeedin - $bpin) - $fipl)} # Ladefreigabe wenn akt. Bat-Ladung UND Eispeisung - Bat-Ladung > Einspeiselimit der Anlage
|
||||||
|
|
||||||
|
if ($inc) { # Einspeiselimit berücksichtigen
|
||||||
|
$target = max ($target, $inc);
|
||||||
|
}
|
||||||
|
|
||||||
$otp->{$bn}{target} = $target;
|
$otp->{$bn}{target} = $target;
|
||||||
|
|
||||||
storeReading ('Battery_ChargeOptTargetPower_'.$bn, $target.' W');
|
storeReading ('Battery_ChargeOptTargetPower_'.$bn, $target.' W');
|
||||||
|
|
||||||
if ($paref->{debug} =~ /batteryManagement/) {
|
if ($paref->{debug} =~ /batteryManagement/) {
|
||||||
my $mn = $otp->{$bn}{maxneed} // 0;
|
my $mn = $otp->{$bn}{maxneed} // 0;
|
||||||
Log3 ($name, 1, "$name DEBUG> ChargeOTP - max OTP Bat $bn: $mn W, sum need: $sn Wh, number hrs: $mv, average: $avg W");
|
Log3 ($name, 1, "$name DEBUG> ChargeOTP - max OTP Bat $bn: $mn W, sum need: $sn Wh, number hrs: $mv, Average for remaining hours: $avg W");
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -11996,10 +12015,11 @@ sub __batChargeOptTargetPower {
|
|||||||
my $otpMargin = $hsurp->{$k}{$bat}{otpMargin};
|
my $otpMargin = $hsurp->{$k}{$bat}{otpMargin};
|
||||||
my $margin = defined $otpMargin ? $otpMargin : SFTYMARGIN_20;
|
my $margin = defined $otpMargin ? $otpMargin : SFTYMARGIN_20;
|
||||||
my $spls = int $hsurp->{$k}{spswh};
|
my $spls = int $hsurp->{$k}{spswh};
|
||||||
my $needmin = $hsurp->{$k}{$bat}{pneedmin};
|
my $needmin = $hsurp->{$k}{$bat}{pneedmin} // BatteryVal ($name, $bat, 'bpinreduced', 0);
|
||||||
|
|
||||||
if ($hsurp->{$k}{nhr} eq '00') { # Target für aktuelle Stunde
|
if ($hsurp->{$k}{nhr} eq '00') { # Target für aktuelle Stunde
|
||||||
$needmin = max ($needmin, $otp->{$bat}{target});
|
my $target = $otp->{$bat}{target} // 0;
|
||||||
|
$needmin = max ($needmin, $target);
|
||||||
}
|
}
|
||||||
|
|
||||||
Log3 ($name, 1, "$name DEBUG> Bat $bat ChargeOTP - hod: $k, Start SoC: $ssoc Wh, Surplus: $spls Wh $sphrs, OTP: $needmin W, safety: $margin %");
|
Log3 ($name, 1, "$name DEBUG> Bat $bat ChargeOTP - hod: $k, Start SoC: $ssoc Wh, Surplus: $spls Wh $sphrs, OTP: $needmin W, safety: $margin %");
|
||||||
@@ -19185,7 +19205,7 @@ sub __substituteIcon {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
$pretxt .= "\n".$htitles{lcactive}{$lang}.": ".(defined $msg2 ? ($msg2 == 1 ? $htitles{simplyes}{$lang} : $htitles{simpleno}{$lang}) : '-');
|
$pretxt .= "\n".$htitles{lcready}{$lang}.": ".(defined $msg2 ? ($msg2 == 1 ? $htitles{simplyes}{$lang} : $htitles{simpleno}{$lang}) : '-');
|
||||||
|
|
||||||
if (defined $pcurr) { # aktueller Zustand
|
if (defined $pcurr) { # aktueller Zustand
|
||||||
if ($pcurr > 0) { # Batterie wird aufgeladen
|
if ($pcurr > 0) { # Batterie wird aufgeladen
|
||||||
@@ -26855,9 +26875,9 @@ to ensure that the system configuration is correct.
|
|||||||
<ul>
|
<ul>
|
||||||
<table>
|
<table>
|
||||||
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
||||||
<tr><td> <b>lowSoc</b> </td><td>lower minimum SoC - The battery is not discharged lower than this value (> 0) </td></tr>
|
<tr><td> <b>lowSoc</b> </td><td>lower minimum SoC - the battery should not be discharged below this value (> 0) </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
<tr><td> <b>upSoC</b> </td><td>upper minimum SoC - The usual value of the optimum SoC tends to be </td></tr>
|
<tr><td> <b>upSoC</b> </td><td>upper minimum SoC - the usual value of the optimum SoC tends to be </td></tr>
|
||||||
<tr><td> </td><td>between 'lowSoC' and 'upSoC' in periods with a high PV surplus </td></tr>
|
<tr><td> </td><td>between 'lowSoC' and 'upSoC' in periods with a high PV surplus </td></tr>
|
||||||
<tr><td> </td><td>and between 'upSoC' and 'maxSoC' in periods with a low PV surplus </td></tr>
|
<tr><td> </td><td>and between 'upSoC' and 'maxSoC' in periods with a low PV surplus </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
@@ -29533,9 +29553,9 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
|||||||
<ul>
|
<ul>
|
||||||
<table>
|
<table>
|
||||||
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
||||||
<tr><td> <b>lowSoc</b> </td><td>unterer Mindest-SoC - Die Batterie wird nicht tiefer als dieser Wert entladen (> 0) </td></tr>
|
<tr><td> <b>lowSoc</b> </td><td>unterer Mindest-SoC - die Batterie soll nicht tiefer als dieser Wert entladen werden (> 0) </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
<tr><td> <b>upSoC</b> </td><td>oberer Mindest-SoC - Der übliche Wert des optimalen SoC bewegt sich in Perioden mit hohen </td></tr>
|
<tr><td> <b>upSoC</b> </td><td>oberer Mindest-SoC - der übliche Wert des optimalen SoC bewegt sich in Perioden mit hohen </td></tr>
|
||||||
<tr><td> </td><td>PV-Überschuß tendenziell zwischen 'lowSoC' und 'upSoC', in Perioden mit geringem PV-Überschuß </td></tr>
|
<tr><td> </td><td>PV-Überschuß tendenziell zwischen 'lowSoC' und 'upSoC', in Perioden mit geringem PV-Überschuß </td></tr>
|
||||||
<tr><td> </td><td>tendenziell zwischen 'upSoC' und 'maxSoC' </td></tr>
|
<tr><td> </td><td>tendenziell zwischen 'upSoC' und 'maxSoC' </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
|
|||||||
Reference in New Issue