From c29f913519d184498cb7a217136dacf6b642e2b7 Mon Sep 17 00:00:00 2001 From: "klaus.schauer" Date: Wed, 12 Sep 2018 17:54:15 +0000 Subject: [PATCH] 00_TCM: new TCM 515 transceiver options added git-svn-id: https://svn.fhem.de/fhem/trunk@17333 2b470e98-0d58-463d-a4d8-8e2adae1ed80 --- fhem/FHEM/00_TCM.pm | 3 +++ 1 file changed, 3 insertions(+) diff --git a/fhem/FHEM/00_TCM.pm b/fhem/FHEM/00_TCM.pm index c06684796..503108620 100755 --- a/fhem/FHEM/00_TCM.pm +++ b/fhem/FHEM/00_TCM.pm @@ -795,6 +795,7 @@ my %gets120 = ( # Get commands TCM 310 my %gets310 = ( "baseID" => {packetType => 5, cmd => "08", BaseID => "1,4", RemainingWriteCycles => "5,1"}, + "dutycycleLimit" => {packetType => 5, cmd => "23", DutyCycle => "1,1", Slots => "2,1", SlotPeriod => "3,2", ActualSlotLeft => "5,2", LoadAfterActual => "7,1"}, "filter" => {packetType => 5, cmd => "0F", "Type:Value" => "1,0,1:4"}, "frequencyInfo" => {packetType => 5, cmd => "25", Frequency => "1,1", Protocol => "2,1"}, "noiseThreshold" => {packetType => 5, cmd => "33", NoiseThreshold => "1,1"}, @@ -1555,6 +1556,8 @@ TCM_Undef($$)
  • baseID
    Get the BaseID. You need this command in order to control EnOcean devices, see the EnOcean paragraph.
  • +
  • dutycycleLimit
    + Read actual duty cycle limit values.
  • filter
    Get supplied filters. Description of the filter parameters, see EnOcean Serial Protocol 3 (ESP3)