Watchdog added + small changes

git-svn-id: svn://svn.code.sf.net/p/fhem/code/trunk@221 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
rudolfkoenig
2008-08-04 13:47:53 +00:00
parent c4cb3d0ef0
commit c703ca49d9
8 changed files with 236 additions and 30 deletions

View File

@@ -44,9 +44,16 @@ hex code needed by fhem.pl?</a><br><br>
<a href="#faq11">11. I'd like to use this sunrise/sunset stuff, can you help
me?</a><br><br>
<a href="#faq12">12. I'd like to switch on the ventilator if the FHT tells me its too hot. How to tell fhem to do that?</a><br><br>
<a href="#faq12">12. I'd like to switch on the ventilator if the FHT tells me
its too hot. How to tell fhem to do that?</a><br><br>
<a href="#faq13">13. I'd like to see directly in the Web frontend if a window
is open. How to do that?</a><br><br>
<a href="#faq14">14. In the summer I get a lot of "actuator:lime-protection"
messages from my FHT80b. How to switch back to the actuator:0% messages?</a>
<br><br>
<a href="#faq12">13. I'd like to see directly in the Web frontend if a window is open. How to do that?</a><br><br>
<br/>
<br/>
@@ -285,5 +292,32 @@ How to do that? (by fwolff)</b>
</pre>
</ul>
<a name="faq14"></a>
<b>14. In the summer I get a lot of "actuator:lime-protection
messages from my FHT80b. How to switch back to the actuator:0% messages?
</b>
<ul>
(Thanks for Martin Fischer for researching)<br>
The problem happens if at the weekly lime-protection time (usually saturday
at 11:00 AM) the desired temperature is lower than the measured temperature.
I think this is an FHT80b firmware bug, a workaround is to set the desired
temperature for a short time higher than the measured temperature.
You can automate it with the following notify:
<pre>
define lime_reset notify .*lime-protection {\
$d = $defs{@}{READINGS}{"desired-temp"}{VAL};;\
$m = $defs{@}{READINGS}{"measured-temp"}{VAL};;\
if($m > $d) {\
fhem("set @ desired-temp 29");;\
fhem("set @ desired-temp $d");;\
}\
}
</pre>
</ul>