Set some HM-CC-TC parameters

git-svn-id: https://fhem.svn.sourceforge.net/svnroot/fhem/trunk/fhem@866 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
rudolfkoenig
2011-03-16 19:34:04 +00:00
parent ca66d6e64d
commit ccf1e7e4f4
4 changed files with 227 additions and 153 deletions

View File

@@ -2445,6 +2445,24 @@ A line ending with \ will be concatenated with the next one, so long lines
set 4Dis text 1 off Kitchen Off<br>
</ul>
</ul></li>
<li>Thermostat (HM-CC-TC)
<ul>
<li>day-temp &lt;tmp&gt;<br>
night-temp &lt;tmp&gt;<br>
Set the day or night temperature. Temp must be between 6 and 30
Centigrade, and precision is half a degree.
<li>tempListSat HH:MM temp 24:00 temp ...<br>
tempListSun HH:MM temp 24:00 temp ...<br>
tempListMon HH:MM temp 24:00 temp ...<br>
tempListTue HH:MM temp 24:00 temp ...<br>
tempListThu HH:MM temp 24:00 temp ...<br>
tempListWed HH:MM temp 24:00 temp ...<br>
tempListFri HH:MM temp 24:00 temp ...<br>
Specify a list of temperature intervals. Up to 24 intervals can be
spacified for each week day, the resolution is 10 Minutes. The
last time spec must always be 24:00.<br>
Example: set th tempListSat 06:00 19 23:00 22.5 24:00 19<br>
</ul></li>
</ul>
<br>