59_LuftdatenInfo: changed request URL to prevent forwarding

git-svn-id: https://svn.fhem.de/fhem/trunk@13981 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
igami
2017-04-13 03:29:18 +00:00
parent d2f135b0e5
commit ebcf52843b

View File

@@ -195,7 +195,7 @@ sub LuftdatenInfo_GetHttpResponse($$) {
if($connection eq "remote"){ if($connection eq "remote"){
my $param = { my $param = {
url => "http://api.luftdaten.info/v1/sensor/$id", url => "http://api.luftdaten.info/v1/sensor/$id/",
timeout => $timeout, timeout => $timeout,
hash => $hash, hash => $hash,
method => "GET", method => "GET",
@@ -301,7 +301,9 @@ sub LuftdatenInfo_ParseHttpResponse($) {
} }
} }
readingsBulkUpdateIfChanged($hash, "latitude", $latitude); readingsBulkUpdateIfChanged($hash, "longitude", $longitude); readingsBulkUpdate($hash, "state", "active"); readingsBulkUpdateIfChanged($hash, "latitude", $latitude);
readingsBulkUpdateIfChanged($hash, "longitude", $longitude);
readingsBulkUpdate($hash, "state", "active");
readingsEndUpdate($hash, 1); readingsEndUpdate($hash, 1);
my $SENSORID2 = InternalVal($SELF, "SENSORID2", undef); my $SENSORID2 = InternalVal($SELF, "SENSORID2", undef);
@@ -420,9 +422,12 @@ sub LuftdatenInfo_statusRequest($) {
(en | <a href="commandref_DE.html#LuftdatenInfo"><u>de</u></a>) (en | <a href="commandref_DE.html#LuftdatenInfo"><u>de</u></a>)
<div> <div>
<ul> <ul>
LuftdatenInfo is the FHEM module to read particulate matter, temperature and humidity values from the self-assembly particulate matter sensors from <a href="http://Luftdaten.info"><u>Luftdaten.info</u></a>.<br> LuftdatenInfo is the FHEM module to read particulate matter, temperature
and humidity values from the self-assembly particulate matter sensors
from <a href="http://Luftdaten.info"><u>Luftdaten.info</u></a>.<br>
The values can be queried directly from the server or locally.<br> The values can be queried directly from the server or locally.<br>
A local query should only be made if the sensor is NOT sendig data to the server, otherwise the sensor may block and need to be restarted.<br> A local query should only be made if the sensor is NOT sendig data to the
server, otherwise the sensor may block and need to be restarted.<br>
<br> <br>
<b>Prerequisites</b> <b>Prerequisites</b>
<ul> <ul>
@@ -438,7 +443,8 @@ sub LuftdatenInfo_statusRequest($) {
define &lt;name&gt; LuftdatenInfo define &lt;name&gt; LuftdatenInfo
(&lt;SDS011sensorID&gt; [&lt;DHT22sensorID&gt;]|&lt;ip&gt;) (&lt;SDS011sensorID&gt; [&lt;DHT22sensorID&gt;]|&lt;ip&gt;)
</code><br> </code><br>
To query the data from the server, the SDS011 SensorID must be specified.<br> To query the data from the server, the SDS011 SensorID must be
specified.<br>
The SensorID stands right at The SensorID stands right at
<a href="http://maps.luftdaten.info/"> <a href="http://maps.luftdaten.info/">
<u>http://maps.luftdaten.info/</u> <u>http://maps.luftdaten.info/</u>