Add keyMatic support for CUL_HM
git-svn-id: https://fhem.svn.sourceforge.net/svnroot/fhem/trunk/fhem@1923 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -3570,6 +3570,29 @@ A line ending with \ will be concatenated with the next one, so long lines
|
||||
# "1234,5" in display with unit 'W'. Symbols scene,phone,bell and clock are active. Backlight flashing fast, Beep is second tone<br>
|
||||
set FB1 display 12345 comma Watt 2 fast scene,phone,bell,clock </ul></code>
|
||||
</li>
|
||||
</ul><br></li>
|
||||
<li>keyMatic<br><br>
|
||||
<ul>The Keymatic uses the AES signed communication. Therefore the control of the Keymatic is only together with the HM-LAN adapter possible. But the CUL can read and react on the status information of the Keymatic.</ul><br>
|
||||
<ul>
|
||||
<li><B>lock</B><br>
|
||||
The lock bolt moves to the locking position<br></li>
|
||||
<li><B>unlock [sec]</B><br>
|
||||
The lock bolt moves to the unlocking position.<br>
|
||||
[sec]: Sets the delay in seconds after the lock automatically locked again.<br>0 - 65535 seconds</li>
|
||||
<li><B>open [sec]</B><br>
|
||||
Unlocked the door so that the door can be opened.<br>
|
||||
[sec]: Sets the delay in seconds after the lock automatically locked again.<br>0 - 65535 seconds</li>
|
||||
<li><B>inhibit-set</B><br>
|
||||
Blocked all directly paired remotes and the hardware buttons of the keyMatic. Now the door lock drive can be controlled only by FHEM.<br></li>
|
||||
<li><B>inhibit-clear</B><br>
|
||||
Deletes the previously set inhibit-flag again.<br><br>
|
||||
Example:
|
||||
<ul><code>
|
||||
# Lock the lock<br>
|
||||
set keymatic lock<br><br>
|
||||
# open the door and relock the lock after 60 seconds<br>
|
||||
set keymatic unlock 60</ul></code>
|
||||
</li>
|
||||
</ul></li>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
Reference in New Issue
Block a user