diff --git a/fhem/docs/commandref_frame.html b/fhem/docs/commandref_frame.html
index 1da373a9e..4cfa42529 100644
--- a/fhem/docs/commandref_frame.html
+++ b/fhem/docs/commandref_frame.html
@@ -450,6 +450,7 @@ attribute list if you want to know if a device supports these attributes.
this attribute is enclused in {}, then it is evaluated. This attribute is
evaluated each time a reading is updated.
+
+
+ This attribute takes a comma-separated list of reading:interval:method:function
+ quadruples. You may use regular expressions for reading. If set, updates for the
+ listed readings are ignored and associated events are suppressed for a black-out period of at
+ least interval seconds. After the black-out period has expired, the reading is
+ updated with a value that is calculated from the values and timestamps of the previously ignored
+ updates within the black-out period as follows:
+
+
| function | description |
|---|---|
| v | the last value encountered |
| v0 | the first value encountered |
| min | the smallest value encountered |
| max | the largest value encountered |
| mean | the arithmetic mean of all values |
| sd | the standard deviation from the mean |
+
+ If method is none, then that's all there is. If method
+ is const or linear, the time-weighted series of values is taken into
+ account instead. The weight is the timespan between two subsequent updates.
+ With the const method, the value is the value of the reading at the beginning of
+ the timespan; with the linear method, the value is the arithmetic average of
+ the values at the beginning and the end of the timespan.
+ Rollovers of black-out periods are handled as one would expect it.
+
+ One would typically use the linear method with the mean function for
+ quantities continuously varying over time like electric power consumption, temperature or speed.
+ For cumulative quantities like energy consumed, rain fallen or distance covered,
+ the none method with the v function is used. The constant
+ method is for discrete quantities that stay constant until the corresponding reading is updated,
+ e.g. counters, switches and the like.
+
+ The event aggregator only takes into consideration those updates that remain after preprocessing
+ according to the event-on-update-reading and event-on-change-reading
+ directives. Besides which, any update of a reading that occurs within a timespan from the preceding
+ update that is smaller than the resolution of FHEM's time granularity is ditched.
+
+ Example:
+ attr myPowerMeter event-aggregator EP_POWER_METER:300:linear:mean,EP_ENERGY_METER:300:none:v
+
+
+
+ This attribute takes a comma-separated list of reading:interval:method:function
+ quadruples. You may use regular expressions for reading. If set, updates for the
+ listed readings are ignored and associated events are suppressed for a black-out period of at
+ least interval seconds. After the black-out period has expired, the reading is
+ updated with a value that is calculated from the values and timestamps of the previously ignored
+ updates within the black-out period as follows:
+
+
| function | description |
|---|---|
| v | the last value encountered |
| v0 | the first value encountered |
| min | the smallest value encountered |
| max | the largest value encountered |
| mean | the arithmetic mean of all values |
| sd | the standard deviation from the mean |
+
+ If method is none, then that's all there is. If method
+ is const or linear, the time-weighted series of values is taken into
+ account instead. The weight is the timespan between two subsequent updates.
+ With the const method, the value is the value of the reading at the beginning of
+ the timespan; with the linear method, the value is the arithmetic average of
+ the values at the beginning and the end of the timespan.
+ Rollovers of black-out periods are handled as one would expect it.
+
+ One would typically use the linear method with the mean function for
+ quantities continuously varying over time like electric power consumption, temperature or speed.
+ For cumulative quantities like energy consumed, rain fallen or distance covered,
+ the none method with the v function is used. The constant
+ method is for discrete quantities that stay constant until the corresponding reading is updated,
+ e.g. counters, switches and the like.
+
+ The event aggregator only takes into consideration those updates that remain after preprocessing
+ according to the event-on-update-reading and event-on-change-reading
+ directives. Besides which, any update of a reading that occurs within a timespan from the preceding
+ update that is smaller than the resolution of FHEM's time granularity is ditched.
+
+ Example:
+ attr myPowerMeter event-aggregator EP_POWER_METER:300:linear:mean,EP_ENERGY_METER:300:none:v
+
+