diff --git a/docs/commandref.html b/docs/commandref.html
index e6e09c31c..44e76d56c 100644
--- a/docs/commandref.html
+++ b/docs/commandref.html
@@ -7210,7 +7210,8 @@ AB600, Duewi, DomiaLite, COCO) and others.
Until now the following Oregon Scientific weather sensors have been tested successfully: BTHR918, BTHR918N, PCR800, RGR918, THGR228N, THGR810, THR128, THWR288A, WTGR800, WGR918. It will also work with many other Oregon sensors supported by RFXtrx433. Please give feedback if you use other sensors.
MS14A (X10 motion sensor. Reports [normal|alert] on the first deviceid (motion sensor) and [on|off] for the second deviceid (light sensor)) X10 (All other x10 devices. Report [on|off] on both deviceids.)ARC (ARC devices. ARC is a protocol used by devices from HomeEasy, KlikAanKlikUit, ByeByeStandBy, Intertechno, ELRO, AB600, Duewi, DomiaLite and COCO with address code wheels. Report [on|off] on both deviceids.)AB400D (ELRO AB400D devices. Report [on|off] on both deviceids.)WAVEMAN (Waveman devices. Report [on|off] on both deviceids.)EMW200 (Chacon EMW200 devices. Report [on|off] on both deviceids.)IMPULS (IMPULS devices. Report [on|off] on both deviceids.)X10 (All other x10 devices. Report [off|on|dim|bright|all_off|all_on] on both deviceids.)ARC (ARC devices. ARC is a protocol used by devices from HomeEasy, KlikAanKlikUit, ByeByeStandBy, Intertechno, ELRO, AB600, Duewi, DomiaLite and COCO with address code wheels. Report [off|on|all_off|all_on|chime].)AB400D (ELRO AB400D devices. Report [off|on].)WAVEMAN (Waveman devices. Report [off|on].)EMW200 (Chacon EMW200 devices. Report [off|on|all_off|all_on].)IMPULS (IMPULS devices. Report [off|on].)AC (AC devices. AC is the protocol used by different brands with units having a learning mode button: KlikAanKlikUit, NEXA, CHACON, HomeEasy UK. Report [off|on|level <NUM>|all_off|all_on|all_level <NUM>].)HOMEEASY (HomeEasy EU devices. Report [off|on|level|all_off|all_on|all_level].)ANSLUT (Anslut devices. Report [off|on|level|all_off|all_on|all_level].)set <name> <value>
+ set <name> <value> [<levelnum>]
value is one of:
off
on
- dim # only for X10
- bright # only for X10
- all_off # only for X10, ARC, EMW200
- all_on # only for X10, ARC, EMW200
+ dim # only for X10, KOPPLA
+ bright # only for X10, KOPPLA
+ all_off # only for X10, ARC, EMW200, AC, HOMEEASY, ANSLUT
+ all_on # only for X10, ARC, EMW200, AC, HOMEEASY, ANSLUT
chime # only for ARC
+ level <levelnum> # only AC, HOMEEASY, ANSLUT: set level to <levelnum> (range: 0=0% to 15=100%)
Example: set Steckdose on