HMConfig:pmsw1 power up action

git-svn-id: https://svn.fhem.de/fhem/trunk@8283 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
martinp876
2015-03-25 10:19:27 +00:00
parent f3e45bfe4a
commit 3e65d3e4a7

View File

@@ -236,7 +236,7 @@ my $K_actDetID = '000000'; # id of actionDetector
,"00A9" => {name=>"HM-PB-6-WM55" ,st=>'remote' ,cyc=>'' ,rxt=>'c:w:l' ,lst=>'1,4' ,chn=>"Btn:1:6",}
,"00AA" => {name=>"HM-SEC-SD-2" ,st=>'smokeDetector' ,cyc=>'99:00' ,rxt=>'c:3' ,lst=>'p' ,chn=>"",}
,"00AB" => {name=>"HM-LC-SW4-BA-PCB" ,st=>'switch' ,cyc=>'' ,rxt=>'b' ,lst=>'1,3' ,chn=>"Sw:1:4",}
,"00AC" => {name=>"HM-ES-PMSw1-Pl" ,st=>'powerMeter' ,cyc=>'00:10' ,rxt=>'' ,lst=>'1:2.3.4.5.6,3:1p,4:3p.4p.5p.6p'
,"00AC" => {name=>"HM-ES-PMSw1-Pl" ,st=>'powerMeter' ,cyc=>'00:10' ,rxt=>'' ,lst=>'1,3:1p,4:3p.4p.5p.6p'
,chn=>"Sw:1:1,Pwr:2:2,SenPwr:3:3,SenI:4:4,SenU:5:5,SenF:6:6"}
,"00AD" => {name=>"HM-TC-IT-WM-W-EU" ,st=>'thermostat' ,cyc=>'00:10' ,rxt=>'c:b' ,lst=>'p:1p.2p.6p.7p,3:3p.6p,1,7:2.3p,8:2,9:2'
,chn=>"Weather:1:1,Climate:2:2,WindowRec:3:3,remote:6:6,SwitchTr:7:7",}
@@ -614,11 +614,11 @@ my $K_actDetID = '000000'; # id of actionDetector
highHoldTime =>{a=>143 ,s=>1 ,l=>1,min=>60 ,max=>7620 ,c=>'fltCvT60' ,f=>'' ,u=>'s' ,d=>0,t=>"hold time on high state"},
evntRelFltTime =>{a=>145 ,s=>1 ,l=>1,min=>1 ,max=>7620 ,c=>'fltCvT60' ,f=>'' ,u=>'s' ,d=>0,t=>"event filter release time "},
triggerMode =>{a=>146.0,s=>1 ,l=>1,min=>0 ,max=>255 ,c=>'lit' ,f=>'' ,u=>'' ,d=>0,t=>"define type of event report ",lit=>{off=>0,sensor=>33,switch=>34,button=>35}},
mtrType =>{a=>149.0,s=>1 ,l=>1,min=>0 ,max=>255 ,c=>'lit' ,f=>'' ,u=>'' ,d=>0,t=>"type of measurement" ,lit=>{gas=>1,IR=>2,LED=>4,unknown=>255}},
mtrConstIr =>{a=>150.0,s=>2 ,l=>1,min=>1 ,max=>65536 ,c=>'' ,f=>'' ,u=>'U/kWh',d=>0,t=>"constant IR"},
mtrConstGas =>{a=>152.0,s=>2 ,l=>1,min=>0001,max=>65.536 ,c=>'' ,f=>1000 ,u=>'m3/I' ,d=>0,t=>"constant gas"},
mtrConstLed =>{a=>154.0,s=>2 ,l=>1,min=>1 ,max=>65536 ,c=>'' ,f=>'' ,u=>'i/kWh',d=>0,t=>"constant led"},
mtrSensIr =>{a=>156.0,s=>1 ,l=>1,min=>-99 ,max=>99 ,c=>'' ,f=>'' ,u=>'%' ,d=>0,t=>"sensiblity IR"},
mtrType =>{a=>149.0,s=>1 ,l=>1,min=>0 ,max=>255 ,c=>'lit' ,f=>'' ,u=>'' ,d=>0,t=>"type of measurement" ,lit=>{gas=>1,IR=>2,LED=>4,unknown=>255}},
mtrConstIr =>{a=>150.0,s=>2 ,l=>1,min=>1 ,max=>65536 ,c=>'' ,f=>'' ,u=>'U/kWh',d=>0,t=>"constant IR"},
mtrConstGas =>{a=>152.0,s=>2 ,l=>1,min=>0001,max=>65.536 ,c=>'' ,f=>1000 ,u=>'m3/I' ,d=>0,t=>"constant gas"},
mtrConstLed =>{a=>154.0,s=>2 ,l=>1,min=>1 ,max=>65536 ,c=>'' ,f=>'' ,u=>'i/kWh',d=>0,t=>"constant led"},
mtrSensIr =>{a=>156.0,s=>1 ,l=>1,min=>-99 ,max=>99 ,c=>'' ,f=>'' ,u=>'%' ,d=>0,t=>"sensiblity IR"},
#un-identified List1
# SEC-WM55 08:01 (AES on?)
@@ -626,6 +626,7 @@ my $K_actDetID = '000000'; # id of actionDetector
# SEC-SC 08:00 ?
# RC19 08:00 ? RC19 Button 08:08
# Bl1PBU 08:00 09:00 10:00
# ES-PMSw1-Pl Ch1 : 93:20 94:45
# logicCombination=>{a=> 89.0,s=>0.5,l=>1,min=>0 ,max=>16 ,c=>'lit' ,f=>'' ,u=>'' ,d=>1,t=>"".
# "inactive=>unused\n".
@@ -926,7 +927,8 @@ $culHmRegType{pushButton} = $culHmRegType{remote};
,"HM-LC-SW4-BA-PCB" =>{ lowBatLimitBA =>1,ledMode =>1,localResDis =>1}
,"HM-Sen-DB-PCB" =>{ ledMode =>1}
,"HM-MOD-Re-8" =>{ lowBatLimitBA3 =>1,ledMode =>1}
,"HM-ES-PMSw1-Pl" =>{ sign =>1}
,"HM-ES-PMSw1-Pl" =>{ sign =>1
,transmitTryMax =>1,powerUpAction =>1,statusInfoMinDly=>1,statusInfoRandom=>1}
,"HM-Sys-sRP-Pl" =>{ compMode =>1}
,"KFM-Display" =>{ CtDlyOn =>1,CtDlyOff =>1