OWX_ASYNC: implement timeout-counter and automatic reconnect
git-svn-id: svn://svn.code.sf.net/p/fhem/code/trunk@6294 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -127,7 +127,7 @@ my %attrs = (
|
||||
);
|
||||
|
||||
#-- some globals needed for the 1-Wire module
|
||||
$owx_async_version=5.9;
|
||||
$owx_async_version=5.10;
|
||||
#-- Debugging 0,1,2,3
|
||||
$owx_async_debug=0;
|
||||
|
||||
@@ -158,7 +158,7 @@ sub OWX_ASYNC_Initialize ($) {
|
||||
$hash->{ReadFn} = "OWX_ASYNC_Read";
|
||||
$hash->{ReadyFn} = "OWX_ASYNC_Ready";
|
||||
$hash->{InitFn} = "OWX_ASYNC_Init";
|
||||
$hash->{AttrList} = "dokick:0,1 interval IODev timeout";
|
||||
$hash->{AttrList} = "dokick:0,1 interval IODev timeout maxtimeouts";
|
||||
main::LoadModule("OWX");
|
||||
}
|
||||
|
||||
@@ -1060,6 +1060,11 @@ sub OWX_ASYNC_RunTasks($) {
|
||||
$task->PT_CANCEL("Timeout");
|
||||
shift @{$current->{queue}};
|
||||
$main::defs{$current->{device}}->{NUMTASKS} = @{$current->{queue}};
|
||||
$master->{TIMEOUTS}++;
|
||||
if ($master->{TIMEOUTS} > AttrVal($master->{NAME},"maxtimeouts",5)) {
|
||||
Log3 ($master->{NAME},3,"OWX_ASYNC_RunTasks: $master->{NAME} maximum number of timeouts exceedet ($master->{TIMEOUTS}), trying to reconnect");
|
||||
OWX_ASYNC_Disconnect($master);
|
||||
}
|
||||
next;
|
||||
} else {
|
||||
Log3 $master->{NAME},5,"OWX_ASYNC_RunTasks: $current->{device} task waiting for data or timeout" if ($owx_async_debug>2);
|
||||
@@ -1084,6 +1089,7 @@ sub OWX_ASYNC_RunTasks($) {
|
||||
my $state = $task->PT_STATE();
|
||||
if ($state == PT_ENDED) {
|
||||
Log3 ($master->{NAME},5,"OWX_ASYNC_RunTasks: $current->{device} task finished");
|
||||
$master->{TIMEOUTS} = 0;
|
||||
} elsif ($state == PT_EXITED) {
|
||||
Log3 ($master->{NAME},4,"OWX_ASYNC_RunTasks: $current->{device} task exited: ".(defined $task->PT_RETVAL() ? $task->PT_RETVAL : "- no retval -"));
|
||||
} elsif ($state == PT_ERROR) {
|
||||
@@ -1214,9 +1220,12 @@ sub OWX_ASYNC_RunTasks($) {
|
||||
<li><a name="OWX_ASYNCdokick"><code>attr <name> dokick 0|1</code></a>
|
||||
<br />1 if the interface regularly kicks thermometers on the bus to do a temperature conversion,
|
||||
and to perform an alarm check, 0 if not</li>
|
||||
<li><a name="OWX_ASYNCIODev"><code>attr <name> IODev <FRM-device></code></a>
|
||||
<li><a name="OWX_ASYNCIODev"><code>attr <name> IODev <FRM-device></code></a>
|
||||
<br />assignes a specific FRM-device to OWX_ASYNC when working through an Arduino.
|
||||
Required only if there is more than one FRM defined.</li>
|
||||
<li><a name="OWX_ASYNCmaxtimeouts"><code>attr <name> maxtimeouts <number></code></a>
|
||||
<br />maximum number of timeouts (in a row) before OWX_ASYNC disconnects itself from the
|
||||
busmaster and tries to establish a new connection</li>
|
||||
<li>Standard attributes <a href="#alias">alias</a>, <a href="#comment">comment</a>, <a
|
||||
href="#event-on-update-reading">event-on-update-reading</a>, <a
|
||||
href="#event-on-change-reading">event-on-change-reading</a>, <a href="#room"
|
||||
|
||||