THZ: fix celle 1clean and 4 new readings for newer pumps (Forum #1188228)
git-svn-id: https://svn.fhem.de/fhem/trunk@25245 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -1,8 +1,8 @@
|
||||
##############################################
|
||||
# 00_THZ
|
||||
# $Id$
|
||||
# by immi 10/2021
|
||||
my $thzversion = "0.197";
|
||||
# by immi 11/2021
|
||||
my $thzversion = "0.198";
|
||||
# this code is based on the hard work of Robert; I just tried to port it
|
||||
# http://robert.penz.name/heat-pump-lwz/
|
||||
########################################################################################
|
||||
@@ -353,7 +353,7 @@ my %parsinghash = (
|
||||
],
|
||||
"0clean" => [["", 8, 2, "hex", 1]
|
||||
],
|
||||
"1clean" => [["", 8, 4, "hex", 1]
|
||||
"1clean" => [["", 8, 4, "hex2int", 1] #fix for celle; handl neg values 20NoV2021
|
||||
],
|
||||
"2opmode" => [["", 8, 2, "opmode", 1]
|
||||
],
|
||||
@@ -779,6 +779,10 @@ my %getsonly539 = ( #info from belu and godmorgon
|
||||
"sFlowRate" => {cmd2=>"0A033B", type =>"1clean", unit =>" cl/min"},
|
||||
"sHumMaskingTime" => {cmd2=>"0A064F", type =>"1clean", unit =>" min"},
|
||||
"sHumThreshold" => {cmd2=>"0A0650", type =>"1clean", unit =>" %"},
|
||||
"sHeatingRelPower" => {cmd2=>"0A069A", type =>"1clean", unit =>" %"},
|
||||
"sComprRelPower" => {cmd2=>"0A069B", type =>"1clean", unit =>" %"},
|
||||
"sComprRotUnlimit" => {cmd2=>"0A069C", type =>"1clean", unit =>" Hz"},
|
||||
"sComprRotLimit" => {cmd2=>"0A069D", type =>"1clean", unit =>" Hz"},
|
||||
"sOutputReduction" => {cmd2=>"0A06A4", type =>"1clean", unit =>" %"},
|
||||
"sOutputIncrease" => {cmd2=>"0A06A5", type =>"1clean", unit =>" %"},
|
||||
"sHumProtection" => {cmd2=>"0A09D1", type =>"1clean", unit =>""},
|
||||
|
||||
Reference in New Issue