76_SolarForecast: contrib Version 1.52.16
git-svn-id: https://svn.fhem.de/fhem/trunk@30060 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
@@ -160,7 +160,7 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"1.52.16"=> "21.06.2025 _genSpecialReadings: new option remainingChargeHrsMinPwrBat_XX ",
|
||||
"1.52.16"=> "21.06.2025 _genSpecialReadings: new option remainingSurplsHrsMinPwrBat_XX ",
|
||||
"1.52.15"=> "20.06.2025 ctrlBatSocManagementXX->loadAbort expanded by unlock condition ",
|
||||
"1.52.14"=> "18.06.2025 _beamGraphic: rework linear and logarithmic normalization of beam height ",
|
||||
"1.52.13"=> "17.06.2025 _genSpecialReadings: new option remainingHrsWoChargeRcmdBat_XX, edit comref ",
|
||||
@@ -1474,12 +1474,12 @@ my %hcsr = (
|
||||
$hcsr{'remainingHrsWoChargeRcmdBat_'.$bn}{unit} = '';
|
||||
$hcsr{'remainingHrsWoChargeRcmdBat_'.$bn}{def} = '-';
|
||||
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{fnr} = 5;
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{fn} = \&NexthoursVal;
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{par} = 'pvfc';
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{par1} = 'confc';
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{unit} = '';
|
||||
$hcsr{'remainingChargeHrsMinPwrBat_'.$bn}{def} = '0';
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{fnr} = 5;
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{fn} = \&NexthoursVal;
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{par} = 'pvfc';
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{par1} = 'confc';
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{unit} = '';
|
||||
$hcsr{'remainingSurplsHrsMinPwrBat_'.$bn}{def} = '0';
|
||||
}
|
||||
|
||||
# Funktiontemplate zur Speicherung von Werten in pvHistory
|
||||
@@ -6477,7 +6477,7 @@ sub _attrcreateSpecialRdgs { ## no critic "not used"
|
||||
return qq{The consumer "consumer$cn" is currently not registered as an active consumer!};
|
||||
}
|
||||
}
|
||||
elsif ($avl =~ /remainingChargeHrsMinPwrBat_/xs) {
|
||||
elsif ($avl =~ /remainingSurplsHrsMinPwrBat_/xs) {
|
||||
my $bn = (split "_", $avl)[1];
|
||||
my $parsed = __parseAttrBatSoc ($name, AttrVal ($name, 'ctrlBatSocManagement'.$bn, undef));
|
||||
my $loadAbort = $parsed->{loadAbort};
|
||||
@@ -14439,7 +14439,7 @@ sub _genSpecialReadings {
|
||||
|
||||
storeReading ($prpo.'_'.$kpi, $n);
|
||||
}
|
||||
elsif ($kpi =~ /remainingChargeHrsMinPwrBat_/xs) {
|
||||
elsif ($kpi =~ /remainingSurplsHrsMinPwrBat_/xs) {
|
||||
my $bn = (split "_", $kpi)[1];
|
||||
my $parsed = __parseAttrBatSoc ($name, AttrVal ($name, 'ctrlBatSocManagement'.$bn, undef));
|
||||
my $loadAbort = $parsed->{loadAbort};
|
||||
@@ -26030,7 +26030,7 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> <b>daysUntilBatteryCare_XX</b> </td><td>Days until the next battery XX maintenance (reaching the charge 'maxSoC' from attribute ctrlBatSocManagementXX) </td></tr>
|
||||
<tr><td> <b>lastretrieval_time</b> </td><td>the last retrieval time of the selected radiation data API </td></tr>
|
||||
<tr><td> <b>lastretrieval_timestamp</b> </td><td>the timestamp of the last retrieval time of the selected radiation data API </td></tr>
|
||||
<tr><td> <b>remainingChargeHrsMinPwrBat_XX</b> </td><td>the remaining number of hours on the current day in which the PV surplus (Wh) is higher than the </td></tr>
|
||||
<tr><td> <b>remainingSurplsHrsMinPwrBat_XX</b> </td><td>the remaining number of hours on the current day in which the PV surplus (Wh) is higher than the </td></tr>
|
||||
<tr><td> </td><td>calculated hourly integral of a minimum charging power <MinPwr> of battery XX. </td></tr>
|
||||
<tr><td> </td><td>The <MinPwr> is specified in the ctrlBatSocManagementXX->loadAbort attribute. </td></tr>
|
||||
<tr><td> <b>remainingHrsWoChargeRcmdBat_XX</b> </td><td>the remaining number of hours without charging recommendation for battery XX on the current day </td></tr>
|
||||
@@ -28669,7 +28669,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> <b>daysUntilBatteryCare_XX</b> </td><td>Tage bis zur nächsten Batterie XX Pflege (Erreichen der Ladung 'maxSoC' aus Attribut ctrlBatSocManagementXX) </td></tr>
|
||||
<tr><td> <b>lastretrieval_time</b> </td><td>der letzte Abrufzeitpunkt der gewählten Strahlungsdaten-API </td></tr>
|
||||
<tr><td> <b>lastretrieval_timestamp</b> </td><td>der Timestamp der letzen Abrufzeitpunkt der gewählten Strahlungsdaten-API </td></tr>
|
||||
<tr><td> <b>remainingChargeHrsMinPwrBat_XX</b> </td><td>die verbleibende Anzahl Stunden am aktuellen Tag, in denen der PV-Überschuß (Wh) höher ist als das </td></tr>
|
||||
<tr><td> <b>remainingSurplsHrsMinPwrBat_XX</b> </td><td>die verbleibende Anzahl Stunden am aktuellen Tag, in denen der PV-Überschuß (Wh) höher ist als das </td></tr>
|
||||
<tr><td> </td><td>kalkulierte Stundenintegral einer minimalen Ladeleistung <MinPwr> der Batterie XX. </td></tr>
|
||||
<tr><td> </td><td>Die Angabe <MinPwr> erfolgt im Attribut ctrlBatSocManagementXX->loadAbort. </td></tr>
|
||||
<tr><td> <b>remainingHrsWoChargeRcmdBat_XX</b> </td><td>die verbleibende Anzahl Stunden ohne Ladeempfehlung für Batterie XX am aktuellen Tag </td></tr>
|
||||
|
||||
Reference in New Issue