Description for MQTT DPS topics for subdevices (cid) behind Tuya Gateway

This commit is contained in:
lehanspb
2023-02-15 12:37:46 +03:00
parent 1d1ab0d62a
commit f6bd28c41a

View File

@@ -159,23 +159,23 @@ This example demostrates DPS values and commands for Tuya Smart Thermostat Radia
```
Thermostat mode:
tuya/zgw1/1a24fkfffe6b4e24/dsp/4/state --> {"4":"auto"}
tuya/zgw1/1a24fkfffe6b4e24/dsp/4/state --> {"4":"auto"}
Possible values: auto/temp_auto/holiday/manual/comfort/eco/BOOST
tuya/zgw1/dps/command <-- {"dps": 4, "set": 4, "cid": "1a24fkfffe6b4e24"}
tuya/zgw1/dps/command <-- {"dps": 4, "set": 4, "cid": "1a24fkfffe6b4e24"}
Temperature Setpoint:
tuya/zgw1/1a24fkfffe6b4e24/dps/2/state --> {"2": 220}
tuya/zgw1/1a24fkfffe6b4e24/dps/2/state --> {"2": 220}
Where 220 - 22.0 Celsius
tuya/zgw1/dps/command <-- {"dps": 2, "set": 220, "cid": "1a24fkfffe6b4e24"}
tuya/zgw1/dps/command <-- {"dps": 2, "set": 220, "cid": "1a24fkfffe6b4e24"}
Current Temperature:
tuya/zgw1/1a24fkfffe6b4e24/dps/3/state --> {"3": 225}
tuya/zgw1/1a24fkfffe6b4e24/dps/3/state --> {"3": 225}
Where 225 - 22.5 Celsius
Valve percent:
tuya/zgw1/1a24fkfffe6b4e24/dps/109/state --> {"109": 30}
tuya/zgw1/1a24fkfffe6b4e24/dps/109/state --> {"109": 30}
Where 30 - 30%
tuya/zgw1/dps/command <-- {"dps": 109, "set": 40, "cid": "1a24fkfffe6b4e24"}
tuya/zgw1/dps/command <-- {"dps": 109, "set": 40, "cid": "1a24fkfffe6b4e24"}
```
## Issues